;-----------------------------------------------------------------------------\ ; ADCP Command File for use with VmDas software. ; ; ADCP type: 75 Khz Ocean Surveyor ; Setup name: Noise testing ; Setup type: ; ; NOTE: Any line beginning with a semicolon in the first ; column is treated as a comment and is ignored by ; the VmDas software. ; ; NOTE: This file is best viewed with a fixed-point font (eg. courier). ;----------------------------------------------------------------------------/ ; Restore factory default settings in the ADCP cr1 ; set the data collection baud rate to 9600 bps, ; no parity, one stop bit, 8 data bits ; NOTE: VmDas sends baud rate change command after all other commands in ; this file, so that it is not made permanent by a CK command. cb411 ; Set for broadband profile mode, single-ping ensembles, ; 85 8-meter bins, 8 meter blanking distance, 390 mm/s ambiguity vel WP00000 NP1 NS1600 NF1000 NN065 BP001 BX15000 ND111100000 TP000150 TE00000300 EZ1020001 EX00000 ED00000 ;WS0800 ;WF0800 ;WN085 ;WV390 ; Enable single-ping bottom track, ; Set maximum bottom search depth to 750 meters ;BP001 ;BX7500 ; output velocity, correlation, echo intensity, percent good ;WD111100000 ; 1.70 seconds between bottom and water pings ;TP000170 ; Four seconds between ensembles ; Since VmDas uses manual pinging, TE is ignored by the ADCP. ; You must set the time between ensemble in the VmDas Communication options ;TE00000400 ; Set to calculate speed-of-sound, no depth sensor, ; external synchro heading sensor, use internal ; transducer temperature sensor ;EZ1020001 ES37 ; 37 ppt for Bermuda ; Output beam data (rotations are done in software) ;EX00010 ; Set transducer depth to 4-m ;ED00040 ; txducer misalign (overridden by VmDas?) ;EA04150 ; save this setup to non-volatile memory in the ADCP ;CK