PSA file: D:\TSalData\TSalProgramFiles\TSal486a.psa Date: 10/23/2010 Instrument configuration file: D:\TSalData\Tsal14May10.xmlcon Configuration report for SBE 21 Seacat Thermosalinograph -------------------------------------------------------- Remote temperature : SBE 3 External voltage channels : 1 Sample interval : 6 seconds NMEA position data added : Yes NMEA depth data added : No NMEA time added : No NMEA device connected to : deck unit Scan time added : Yes 1) Frequency 0, Temperature Serial number : 1578 Calibrated on : 16-Dec-08 G : 4.19556271e-003 H : 5.93127424e-004 I : 3.32790121e-006 J : -1.98444679e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 2) Frequency 1, Conductivity Serial number : 1578 Calibrated on : 16-Dec-08 G : -4.02856631e+000 H : 4.80743581e-001 I : 1.08612788e-003 J : -2.20827085e-005 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 3) Frequency 2, Temperature, 2 Serial number : 0604 Calibrated on : 21Apr10 G : 4.79991705e-003 H : 7.10981900e-004 I : 4.78180225e-005 J : 6.02515204e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 4) A/D voltage 0, Fluorometer, Turner 10-Au-005 Serial number : 6763 Calibrated on : Oct 2004 Full scale voltage : 5.000000 Zero point concentration : 0.000000 Full scale concentration : 0.000000 --------------------------------------------- Data Acquisition: Archive data: YES Delay archiving: NO Data archive: D:\TSalData\13Oct10a.hex Timeout (seconds) at startup: 20 Timeout (seconds) between scans: 20 --------------------------------------------- Instrument port configuration: Port = COM1 Baud rate = 4800 Parity = E Data bits = 7 Stop bits = 1 --------------------------------------------- Water Sampler Data: Water Sampler Type: None --------------------------------------------- Header information: Header Choice = Prompt for Header Information prompt 0 = Ship: R/V ENDEAVOR prompt 1 = Cruise: EN486 prompt 2 = Chief Scientist: Keafer --------------------------------------------- TCP/IP - port numbers: Data acquisition: Data port: 49163 Status port: 49165 Command port: 49164 Remote bottle firing: Command port: 49167 Status port: 49168 Remote data publishing: Converted data port: 49161 Raw data port: 49160 --------------------------------------------- Miscellaneous data for calculations Depth and Average Sound Velocity Latitude when NMEA is not available: 41.500000 Average Sound Velocity Minimum pressure [db]: 20.000000 Minimum salinity [psu]: 20.000000 Pressure window size [db]: 20.000000 Time window size [s]: 60.000000 Descent and Acceleration Window size [s]: 2.000000 Plume Anomaly Theta-B: 0.000000 Salinity-B 0.000000 Theta-Z / Salinity-Z 0.000000 Reference pressure [db] 0.000000 Oxygen Window size [s]: 2.000000 Apply hysteresis correction: 1 Apply Tau correction: 1 Potential Temperature Anomaly A0: 0.000000 A1: 0.000000 A1 Multiplier: Salinity --------------------------------------------- Serial Data Output: Output data to serial port: YES Seconds between updates: 0.000000 Port = COM2 Baud rate = 9600 Parity = N Data bits = 7 Stop bits = 1 Variables: Digits Variable Name [units] ------ --------------------- 5 Conductivity [S/m] 4 Temperature [ITS-90, deg C] 4 Salinity, Practical [PSU] 4 Temperature, 2 [ITS-90, deg C] 5 Voltage 0 1 Sound Velocity [Chen-Millero, m/s] --------------------------------------------- Mark Variables: Variables: Digits Variable Name [units] ------ --------------------- 0 Scan Count 7 Julian Days 5 Temperature [ITS-90, deg C] 5 Temperature, 2 [ITS-90, deg C] 7 Conductivity [S/m] 5 Voltage 0 5 Salinity, Practical [PSU] 5 Density [sigma-t, Kg/m^3 ] 6 Latitude [deg] 6 Longitude [deg] 6 Time, Elapsed [hours] --------------------------------------------- Shared File Output: Output data to shared file: NO --------------------------------------------- TCP/IP Output: Raw data: Output raw data to socket: NO XML wrapper and settings: NO Seconds between raw data updates: 0.000000 Converted data: Output converted data to socket: NO XML format: NO --------------------------------------------- SBE 11plus Deck Unit Alarms Enable minimum pressure alarm: NO Enable maximum pressure alarm: NO Enable altimeter alarm: NO --------------------------------------------- SBE 14 Remote Display Enable SBE 14 Remote Display: NO --------------------------------------------- PC Alarms Enable minimum pressure alarm: NO Enable maximum pressure alarm: NO Enable altimeter alarm: NO Enable bottom contact alarm: NO Alarm uses PC sound card. --------------------------------------------- Options: Prompt to save program setup changes: YES Automatically save program setup changes on exit: NO Confirm instrument configuration change: YES Confirm display setup changes: YES Confirm output file overwrite: YES Check scan length: YES Compare serial numbers: YES Maximized plot may cover Seasave: NO