Date: 09/18/2006 ASCII file: C:\olga\tioga_2005\ti096\CTD\rename\TI096.con Configuration report for SBE 911/917 plus CTD --------------------------------------------- Frequency channels suppressed : 0 Voltage words suppressed : 0 Computer interface : RS-232C Scans to average : 1 Surface PAR voltage added : Yes NMEA position data added : Yes Scan time added : No 1) Frequency 0, Temperature Serial number : 4491 Calibrated on : 04/22/05 G : 4.42645996e-003 H : 6.46332797e-004 I : 2.25518369e-005 J : 1.93512746e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 2) Frequency 1, Conductivity Serial number : 3009 Calibrated on : 04/21/05 G : -1.04811547e+001 H : 1.48661679e+000 I : 5.79021090e-004 J : 3.39216943e-005 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 3) Frequency 2, Pressure, Digiquartz with TC Serial number : 94763 Calibrated on : 05/12/04 C1 : -4.617992e+004 C2 : -7.341121e-001 C3 : 1.340470e-002 D1 : 3.758800e-002 D2 : 0.000000e+000 T1 : 3.017251e+001 T2 : -4.619284e-004 T3 : 4.108730e-006 T4 : 5.343720e-010 T5 : 0.000000e+000 Slope : 1.00000000 Offset : 0.00000 AD590M : 1.278360e-002 AD590B : -8.936226e+000 4) Frequency 3, Temperature, 2 Serial number : 4492 Calibrated on : 04/22/05 G : 4.33937099e-003 H : 6.34022002e-004 I : 2.07537033e-005 J : 1.81926949e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 5) Frequency 4, Conductivity, 2 Serial number : 3073 Calibrated on : 04/07/05 G : -1.04696985e+001 H : 1.25176633e+000 I : 2.32639445e-004 J : 3.88711408e-005 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 6) A/D voltage 0, User Polynomial Serial number : 0304 Calibrated on : 04/29/05 Sensor name : Fluorometer, Wetlab ECO-AFL/FL A0 : 0.07400000 A1 : 11.00000000 A2 : 0.00000000 A3 : 0.00000000 7) A/D voltage 1, User Polynomial, 2 Serial number : 0304 Calibrated on : 04/29/05 Sensor name : Turbidity A0 : -0.28500000 A1 : 5.00000000 A2 : 0.00000000 A3 : 0.00000000 8) A/D voltage 2, PAR/Irradiance, Biospherical/Licor Serial number : 0854 Calibrated on : 04/13/05 M : 1.00000000 B : 0.00000000 Calibration constant : 20040000000.00000000 Multiplier : 1.00000000 Offset : -0.77108000 9) A/D voltage 3, Transmissometer, Chelsea/Seatech/Wetlab CStar Serial number : 0854 Calibrated on : 04/13/05 M : 22.0982 B : -1.2596 Path length : 0.250 10) A/D voltage 4, Altimeter Serial number : 1162 Calibrated on : 05/02/05 Scale factor : 15.000 Offset : 0.000 11) A/D voltage 5, Oxygen, SBE 43 Serial number : 0723 Calibrated on : 04/23/05 Soc : 4.0420e-001 Boc : 0.0000 Offset : -0.4878 Tcor : 0.0000 Pcor : 1.35e-004 Tau : 0.0 12) A/D voltage 6, Free 13) A/D voltage 7, Free 14) SPAR voltage, Unavailable 15) SPAR voltage, SPAR/Surface Irradiance Serial number : 6294 Calibrated on : 1999 Conversion factor : 100674000000000000.00000000 Ratio multiplier : 1671.77000000