PSA file: C:\Documents and Settings\Marshall\Application Data\Sea-Bird\Seasave\Seasave_1.psa Date: 08/03/2010 Instrument configuration file: C:\iFolder\work\Caldata\cruise_packs\OC468-2-Montoya-090462\090462-20100803.con Configuration report for SBE 911plus/917plus CTD ------------------------------------------------ Frequency channels suppressed : 0 Voltage words suppressed : 0 Computer interface : RS-232C Scans to average : 1 NMEA position data added : Yes NMEA depth data added : No NMEA time added : No NMEA device connected to : deck unit Surface PAR voltage added : Yes Scan time added : No 1) Frequency 0, Temperature Serial number : 4195 Calibrated on : 23-Jan-10 G : 4.37127659e-003 H : 6.44072063e-004 I : 2.25168439e-005 J : 1.88097395e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 2) Frequency 1, Conductivity Serial number : 2670 Calibrated on : 12-Jan-10 G : -1.04351874e+001 H : 1.39740257e+000 I : -7.99997539e-004 J : 1.28162576e-004 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 3) Frequency 2, Pressure, Digiquartz with TC Serial number : 63505 SBE090462 Calibrated on : 12/23/2002 C1 : -4.872453e+004 C2 : 2.143123e-002 C3 : 1.347220e-002 D1 : 3.959500e-002 D2 : 0.000000e+000 T1 : 2.994567e+001 T2 : -2.488396e-004 T3 : 3.985300e-006 T4 : 7.998620e-010 T5 : 0.000000e+000 Slope : 0.99992000 Offset : -1.29630 AD590M : 1.282050e-002 AD590B : -9.111539e+000 4) Frequency 3, Temperature, 2 Serial number : 4481 Calibrated on : 12-Jan-10 G : 4.33492523e-003 H : 6.37136216e-004 I : 2.07661802e-005 J : 1.71173431e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 5) Frequency 4, Conductivity, 2 Serial number : 2880 Calibrated on : 12-Jan-10 G : -1.06602669e+001 H : 1.44142660e+000 I : 2.34005419e-004 J : 5.73830122e-005 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 6) A/D voltage 0, Fluorometer, Wetlab ECO-AFL/FL Serial number : FLRTD-364 Calibrated on : 2009-06-01 Vblank : 0.0410 Scale factor : 1.30000000e+001 7) A/D voltage 1, Transmissometer, Chelsea/Seatech/Wetlab CStar Serial number : CST-1118DR Calibrated on : 2008-04-30 M : 21.4270 B : -1.3070 Path length : 0.250 8) A/D voltage 2, Free 9) A/D voltage 3, Free 10) A/D voltage 4, Altimeter Serial number : 1162 Calibrated on : Scale factor : 15.000 Offset : 0.000 11) A/D voltage 5, Oxygen, SBE 43 Serial number : 0723 Calibrated on : 12-Feb-10p Equation : Sea-Bird Soc : 5.07200e-001 Offset : -5.09700e-001 A : -1.49330e-003 B : 5.41770e-005 C : -1.38590e-006 E : 3.60000e-002 Tau20 : 1.02000e+000 D1 : 1.92630e-004 D2 : -4.64800e-002 H1 : -3.30000e-002 H2 : 5.00000e+003 H3 : 1.45000e+003 12) A/D voltage 6, Free 13) A/D voltage 7, Free 14) SPAR voltage, Unavailable 15) SPAR voltage, SPAR/Surface Irradiance Serial number : QSR-2200 s/n 20314 Calibrated on : 2009-03-24 Conversion factor : 1661.37000000 Ratio multiplier : 1.00000000 --------------------------------------------- Pump Control This setting is only applicable to a custom build of the SBE 9plus. Enable pump on / pump off commands: NO --------------------------------------------- Data Acquisition: Archive data: YES Delay archiving: NO Data archive: Timeout (seconds) at startup: 20 Timeout (seconds) between scans: 20 --------------------------------------------- Instrument port configuration: Port = COM1 Baud rate = 9600 Parity = N Data bits = 8 Stop bits = 1 --------------------------------------------- Water Sampler Data: Water Sampler Type: None --------------------------------------------- Header information: Header Choice = Prompt for Header Information --------------------------------------------- TCP/IP - port numbers: Data acquisition: Data port: 49163 Status port: 49165 Command port: 49164 Remote bottle firing: Command port: 49167 Status port: 49168 Remote data publishing: Converted data port: 49161 Raw data port: 49160 --------------------------------------------- Miscellaneous data for calculations Depth and Average Sound Velocity Latitude when NMEA is not available: 0.00000000 Average Sound Velocity Minimum pressure [db]: 20.00000000 Minimum salinity [psu]: 20.00000000 Pressure window size [db]: 20.00000000 Time window size [s]: 60.00000000 Descent and Acceleration Window size [s]: 2.00000000 Plume Anomaly Theta-B: 0.00000000 Salinity-B 0.00000000 Theta-Z / Salinity-Z 0.00000000 Reference pressure [db] 0.00000000 Oxygen Window size [s]: 2.00000000 Apply hysteresis correction: 1 Apply Tau correction: 1 Potential Temperature Anomaly A0: 0.00000000 A1: 0.00000000 A1 Multiplier: Salinity --------------------------------------------- Serial Data Output: Output data to serial port: NO --------------------------------------------- Mark Variables: No variables are selected. --------------------------------------------- Shared File Output: Output data to shared file: NO --------------------------------------------- TCP/IP Output: Raw data: Output raw data to socket: NO XML wrapper and settings: NO Seconds between raw data updates: 0.00000000 Converted data: Output converted data to socket: NO XML format: NO --------------------------------------------- SBE 11plus Deck Unit Alarms Enable minimum pressure alarm: NO Enable maximum pressure alarm: NO Enable altimeter alarm: NO --------------------------------------------- SBE 14 Remote Display Enable SBE 14 Remote Display: NO --------------------------------------------- PC Alarms Enable minimum pressure alarm: NO Enable maximum pressure alarm: NO Enable altimeter alarm: NO Enable bottom contact alarm: NO Alarm uses PC sound card. --------------------------------------------- Options: Prompt to save program setup changes: YES Automatically save program setup changes on exit: NO Confirm instrument configuration change: YES Confirm display setup changes: YES Confirm output file overwrite: YES Check scan length: YES Compare serial numbers: YES Maximized plot may cover Seasave: NO