Date: 03/12/2010

Instrument configuration file: D:\IFOLDER-20100303\work\Caldata\confiles\090462\090462-20100303.con

Configuration report for SBE 911plus/917plus CTD
------------------------------------------------

Frequency channels suppressed : 0
Voltage words suppressed      : 0
Computer interface            : RS-232C
Scans to average              : 1
NMEA position data added      : Yes
NMEA depth data added         : No
NMEA time added               : No
NMEA device connected to      : deck unit
Surface PAR voltage added     : Yes
Scan time added               : No

1) Frequency 0, Temperature

   Serial number : 4195
   Calibrated on : 23-Jan-10 
   G             : 4.37127659e-003
   H             : 6.44072063e-004
   I             : 2.25168439e-005
   J             : 1.88097395e-006
   F0            : 1000.000
   Slope         : 1.00000000
   Offset        : 0.0000

2) Frequency 1, Conductivity

   Serial number : 2670
   Calibrated on : 12-Jan-10 
   G             : -1.04351874e+001
   H             : 1.39740257e+000
   I             : -7.99997539e-004
   J             : 1.28162576e-004
   CTcor         : 3.2500e-006
   CPcor         : -9.57000000e-008
   Slope         : 1.00000000
   Offset        : 0.00000

3) Frequency 2, Pressure, Digiquartz with TC

   Serial number : 63505 SBE090462
   Calibrated on : 12/23/2002
   C1            : -4.872453e+004
   C2            : 2.143123e-002
   C3            : 1.347220e-002
   D1            : 3.959500e-002
   D2            : 0.000000e+000
   T1            : 2.994567e+001
   T2            : -2.488396e-004
   T3            : 3.985300e-006
   T4            : 7.998620e-010
   T5            : 0.000000e+000
   Slope         : 0.99992000
   Offset        : -1.29630
   AD590M        : 1.282050e-002
   AD590B        : -9.111539e+000

4) Frequency 3, Temperature, 2

   Serial number : 4481
   Calibrated on : 12-Jan-10 
   G             : 4.33492523e-003
   H             : 6.37136216e-004
   I             : 2.07661802e-005
   J             : 1.71173431e-006
   F0            : 1000.000
   Slope         : 1.00000000
   Offset        : 0.0000

5) Frequency 4, Conductivity, 2

   Serial number : 2880
   Calibrated on : 12-Jan-10 
   G             : -1.06602669e+001
   H             : 1.44142660e+000
   I             : 2.34005419e-004
   J             : 5.73830122e-005
   CTcor         : 3.2500e-006
   CPcor         : -9.57000000e-008
   Slope         : 1.00000000
   Offset        : 0.00000

6) A/D voltage 0, Fluorometer, Wetlab ECO-AFL/FL

   Serial number : FLRTD-364
   Calibrated on : 2009-06-01
   Vblank        : 0.0410
   Scale factor  : 1.30000000e+001

7) A/D voltage 1, Transmissometer, Chelsea/Seatech/Wetlab CStar

   Serial number : CST-1118DR
   Calibrated on : 2008-04-30
   M             : 21.4270
   B             : -1.3070
   Path length   : 0.250

8) A/D voltage 2, Free

9) A/D voltage 3, Free

10) A/D voltage 4, Altimeter

    Serial number : 1162
    Calibrated on : 
    Scale factor  : 15.000
    Offset        : 0.000

11) A/D voltage 5, Oxygen, SBE 43

    Serial number : 0723
    Calibrated on : 12-Feb-10p
    Equation      : Sea-Bird
    Soc           : 5.07200e-001
    Offset        : -5.09700e-001
    A             : -1.49330e-003
    B             : 5.41770e-005
    C             : -1.38590e-006
    E             : 3.60000e-002
    Tau20         : 1.02000e+000
    D1            : 1.92630e-004
    D2            : -4.64800e-002
    H1            : -3.30000e-002
    H2            : 5.00000e+003
    H3            : 1.45000e+003

12) A/D voltage 6, Free

13) A/D voltage 7, Free

14) SPAR voltage, Unavailable

15) SPAR voltage, SPAR/Surface Irradiance

    Serial number     : QSR-2200 s/n 20314
    Calibrated on     : 2009-03-24
    Conversion factor : 1661.37000000
    Ratio multiplier  : 1.00000000