Calliope Data The starboard Vaisala sensor stopped working for approximately an hour on august 2, 0930-1100 gmt. I reset the power to the rs485 loop in the main science Jbox and the sensor came back. 150ADCP Stopped collecting data July 31, 2010 at 1300 hrs gmt. 1. First time it stopped, I just restarted data collection and it came back happy for about an hour, 2. Second time around I stopped data collection and when I did a bunch of gibberish was sent to the screen, I repowered the deck unit and restarted data aquisistion, but i did not last very long 3. 1230 gmt turned bottom tracking off and restarted data aquisisition.. it lasted for 2 seonds.. 75 is working fine.. 4. Resat connector and turned back on, it only collected data for almost 2 minutes, then the red screen of death. Secured for remainder of cruise. The adcp cruise data was saved as: adcp_first_set data w/ 150ADCP and 75ADCP and troubleshooting towards the end adcp data w/ 75ADCP CTD CTD S/N 484 was used for the cruise, configuration files: oc467/ctd/doc/configs/ctd_484 CTD worked well for the cruise, occasionally bottle did not fire and one leaky bottle