C:\DATA\>dir Volume in drive C has no label Volume Serial Number is 7534-7AA6 Directory of C:\DATA\ . 10-25-11 1:28p .. 10-25-11 1:28p CAST0001.ENG 4,898 01-15-12 4:59a SH__0001.HEX 111,021 01-15-12 4:59a OCR_1.DAT 184,355 01-15-12 4:59a 3 file(s) 300,274 bytes 2 dir(s) 258,084,864 bytes free C:\DATA\>del *.eng C:\DATA\>del *.hex C:\DATA\>del *.dat C:\DATA\>dir Volume in drive C has no label Volume Serial Number is 7534-7AA6 Directory of C:\DATA\ . 10-25-11 1:28p .. 10-25-11 1:28p 0 file(s) 0 bytes 2 dir(s) 258,396,160 bytes free C:\DATA\>cd .. C:\>dir Volume in drive C has no label Volume Serial Number is 7534-7AA6 Directory of C:\ OCR504.HDR 1,294 10-19-11 1:57p TESTFILE.001 0 01-15-12 5:10a DATA 10-25-11 1:28p CONFIG.TXT 191 01-15-12 2:17a OPFILE.TXT 13 01-15-12 5:10a HEADER.TXT 375 01-14-12 8:23p OCR_2.DAT 5,147 01-15-12 5:00a CAST0002.ENG 2,542 01-15-12 5:10a SH__0002.HEX 10,031 01-15-12 5:00a 8 file(s) 19,593 bytes 1 dir(s) 258,396,160 bytes free C:\>del *.eng C:\>del *.dat C:\>del *.hex C:\>dir Volume in drive C has no label Volume Serial Number is 7534-7AA6 Directory of C:\ OCR504.HDR 1,294 10-19-11 1:57p TESTFILE.001 0 01-15-12 5:10a DATA 10-25-11 1:28p CONFIG.TXT 191 01-15-12 2:17a OPFILE.TXT 13 01-15-12 5:10a HEADER.TXT 375 01-14-12 8:23p 5 file(s) 1,873 bytes 1 dir(s) 258,420,736 bytes free C:\>date Clock reads: Sunday, January 15, 2012 08:07:04 am C:\>? date DATE [mm-dd-yy[yy] [hh:mm:ss [a|p]]] [/I] [/E] [/U] [/M] [/C] [/P] Set the real time clock from the date (and optionally time) based on parameters in the form: [mm/dd/yy[yy] [hh:mm:ss [a|p]]. Type DATE without parameters to display the current date settings /U Expect USA date format (default): mm/dd/yy /I Expect ISO date format: yy/mm/dd /E Expect European date format: dd/mm/yy /M Military 24 hour time format /C Civilian 12 hour time format /P Prompt for date and time C:\>date 01-15-2012 08:08:10 Clock reads: Sunday, January 15, 2012 08:08:10 am C:\>date Clock reads: Sunday, January 15, 2012 08:08:15 am C:\> Nortek Vec: DISABLED EPS Mapper: DISABLED MAVS: DISABLED OCR 504: *ENABLED* IMM: DISABLED Upload Auxilary Files: *ENABLED* OCR504 uart opened Configuration file settings: ---------------------------- Number of parameters to read: 8 First cycle set for: Sun Jan 15 04:00:00 2012 Clamp test delay set for: 1 minutes Cycle interval set for: 60 minutes Ascending timeout set for: 800 seconds Ascending trigger depth set for: 8.0 meters Descending timeout set for: 600 seconds Descending trigger depth set for: 50.0 meters Time to wait at surface set for: 0 seconds Stored calibration settings: ---------------------------- Motor current coefficient: 0.000755 Aux 1 current coefficient: 0.000220 Aux 2 current coefficient: 0.000220 Aux 3 current coefficient: 0.000220 Aux 4 current coefficient: 0.000219 Switched battery voltage coefficient: 0.004305 Switched aux voltage coefficient: 0.004290 Depth coefficient: 0.106744 Motor current offset: -15 Aux 1 current offset: 13 Aux 2 current offset: 32 Aux 3 current offset: 6 Aux 4 current offset: 21 Switched battery voltage offset: -34 Switched aux voltage offset: -1 Depth offset: 808 Directory 'DATA' found. SeaHorse II Ver. 2.091 Next cycle will start 5 seconds from now... Press the '&' key to bypass sampling and enter the main menu... Waiting... SeaHorse II v2.091 [Oct 19 2011 15:33:35] Configured CTD: Seabird SBE 19 Plus (9600_N_8_1) ---------------------------------------------- Format flash card [A] Display directory [B] Create configuration file [G] Create user header [H] Deploy SeaHorse [D] Display system data [E] Select free mode [F] Select climb mode [C] Instrument direct mode [M] Configure CTD [N] Update system calibration [U] View system calibration [V] Seahorse calibration [S] Select Payload Instruments [P] Operational Parameters [O] Test IMM [I] Power FRRf ON [J] Power FRRf OFF [K] Quit [Q] Enter selection........... [ ] ? g Entering user configuration setup Enter time (mm/dd/yyyy hh:mm:ss) of first cycle [01/15/2012 08:11:01] ? 01/15/2012 10:00:00 First cycle set for: Sun Jan 15 10:00:00 2012 Enter the number of minutes to delay for the clamp test [1] ? Clamp test delay set for 1 minutes Enter sampling interval in minutes [360] ? 60 Sampling interval is 60 minutes Enter the time out (in seconds) for the up cast [800] ? Time out for up cast is set at 800 seconds Enter minimum depth to trigger the up cast termination [4.000000] ? 8 Minimum depth trigger is set at 8.0 meters Enter the time out (in seconds) for the down cast) [600] ? Time out for down cast is set at 600 seconds Enter maximum depth to trigger the down cast termination [50.000000] ? Maximum depth trigger is set at 50.0 meters Enter the time (in seconds) to wait at the surface for offload attempts [0] ? Time at surface is set at 0 seconds The configuration string is as follows: parameters: 8 first cycle: 01/15/2012 10:00:00 test cycle: 1 cycle interval: 60 ascend timeout: 800 ascend trigger depth: 8.0 descend timeout: 600 descend trigger depth: 50.0 surface time: 0 Do you want to save the configuration to a file? If so, then this file will be used for future deployments [Y] ? Configuration data file written Opening and reading configuration file for confirmation... Configuration file settings: ---------------------------- Number of parameters to read: 8 First cycle set for: Sun Jan 15 10:00:00 2012 Clamp test delay set for: 1 minutes Cycle interval set for: 60 minutes Ascending timeout set for: 800 seconds Ascending trigger depth set for: 8.0 meters Descending timeout set for: 600 seconds Descending trigger depth set for: 50.0 meters Time to wait at surface set for: 0 seconds Press to continue... SeaHorse II v2.091 [Oct 19 2011 15:33:35] Configured CTD: Seabird SBE 19 Plus (9600_N_8_1) ---------------------------------------------- Format flash card [A] Display directory [B] Create configuration file [G] Create user header [H] Deploy SeaHorse [D] Display system data [E] Select free mode [F] Select climb mode [C] Instrument direct mode [M] Configure CTD [N] Update system calibration [U] View system calibration [V] Seahorse calibration [S] Select Payload Instruments [P] Operational Parameters [O] Test IMM [I] Power FRRf ON [J] Power FRRf OFF [K] Quit [Q] Enter selection........... [ ] ? m Instrument Direct Menu: ----------------------- Connect to CTD [C] Connect to OCR504 [O] Quit to main menu [Q] enter selection....... [C] ? c Entering instrument ascii direct mode Press ~ to exit SeacatPlus S>time out SeacatPlus S>ds SeacatPlus V 1.3a SERIAL NO. 4142 15 Jan 2012 08:12:36 vbatt = 13.2, vlith = 7.7, ioper = 61.4 ma, ipump = 86.1 ma, iext01 = 4.5 ma, iext23 = 38.5 ma, status = not logging number of scans to average = 1 samples = 3652, free = 555042, casts = 3 mode = profile, minimum cond freq = 3145, pump delay = 40 sec ignore magnetic switch = yes battery type = ALKALINE, battery cutoff = 7.5 volts pressure sensor = strain gauge, range = 508.0 SBE 38 = no, Gas Tension Device = no Ext Volt 0 = yes, Ext Volt 1 = no, Ext Volt 2 = yes, Ext Volt 3 = no echo commands = yes output format = raw HEX S>initlogging S>initlogging S>ds SeacatPlus V 1.3a SERIAL NO. 4142 15 Jan 2012 08:12:57 vbatt = 13.2, vlith = 7.7, ioper = 61.4 ma, ipump = 86.9 ma, iext01 = 4.2 ma, iext23 = 38.4 ma, status = not logging number of scans to average = 1 samples = 0, free = 558694, casts = 0 mode = profile, minimum cond freq = 3145, pump delay = 40 sec ignore magnetic switch = yes battery type = ALKALINE, battery cutoff = 7.5 volts pressure sensor = strain gauge, range = 508.0 SBE 38 = no, Gas Tension Device = no Ext Volt 0 = yes, Ext Volt 1 = no, Ext Volt 2 = yes, Ext Volt 3 = no echo commands = yes output format = raw HEX S> SBE19plus: Shutdown Sending STOP\r, 1/30 STOP S> '>' prompt detected (1/30) SBE19plus: enter quiescent state Sending QS\r, 1/1 QS Timeout on attempt 1 Instrument Direct Menu: ----------------------- Connect to CTD [C] Connect to OCR504 [O] Quit to main menu [Q] enter selection....... [C] ? q SeaHorse II v2.091 [Oct 19 2011 15:33:35] Configured CTD: Seabird SBE 19 Plus (9600_N_8_1) ---------------------------------------------- Format flash card [A] Display directory [B] Create configuration file [G] Create user header [H] Deploy SeaHorse [D] Display system data [E] Select free mode [F] Select climb mode [C] Instrument direct mode [M] Configure CTD [N] Update system calibration [U] View system calibration [V] Seahorse calibration [S] Select Payload Instruments [P] Operational Parameters [O] Test IMM [I] Power FRRf ON [J] Power FRRf OFF [K] Quit [Q] Enter selection........... [ ] ? d SeaHorse Deployment Setup Enter new time (mm/dd/yyyy hh:mm:ss) if time is wrong [01/15/2012 08:13:34] ? System time has not been changed System clock curently reads: Sun Jan 15 08:13:45 2012 Do you want to test the CTD [Y] ? SBE19plus: Powering Sending STOP\r, 1/30 Timeout on attempt 1 Sending , 2/30 Timeout on attempt 2 Sending , 3/30 SSeacatPlus S> '>' prompt detected (3/30) SBE19plus: Clock-Sync Sending \r, 1/30 S> '>' prompt detected (1/30) Sending MMDDYY=011512\r, 1/30 MMDDYY=011512 S> '>' prompt detected (1/30) Sending HHMMSS=081400, 1/1 Sending \r, 1/1 S> '>' prompt detected (1/1) SBE19plus: Clock-Sync complete. Sending STARTNOW\r, 1/20 STARTNOW S> '>' prompt detected (1/20) CTD ready. Entering instrument ascii direct mode Press ~ to exit 07DA4911871107F16648A351E00AB4 07DA4B116FF307F16648A551CB0A94 07DA4A11907707F16648A251DD0A6F 07DA4C11D4EE07F16748A551F10A5B 07DA4B1217D307F16648A551C80A35 07DA4C12305107F16648A451EC0A12 07DA4E1224F507F16648A651ED0A13 07DA511220EE07F16548A651C409FA 07DA50121ED307F16648A651E509DB 07DA521241ED07F16848A451EB09CA 07DA52127B9707F16648A651ED09AF 07DA5512C34B07F16648A651CF098F 07DA5512F92507F16548A851D60970 SBE19plus: Shutdown Sending STOP\r, 1/30 S> '>' prompt detected (1/30) SBE19plus: enter quiescent state Sending QS\r, 1/1 QS Timeout on attempt 1 CTD test complete...continuing with deployment setup. User header: ** Cruise: NBP12-01 ** Station: 1 ** Ship: RVIB Nathaniel B Palmer ** Chief_Scientist: Greenan ** Organization: DFO ** Area_of_Operation: Ross Sea ** Package: SeaHorse/SBE19plus CTD/WetStar/SBE43-DO/Satlantic OCR504i/FRRF ** Mooring_Number: 1 ** Latitude: -76 29.0 ** Longtitude: 171 06.0 ** Sounding: 800 ** Profile_Direction: up ** Notes: Configuration file settings: ---------------------------- Number of parameters to read: 8 First cycle set for: Sun Jan 15 10:00:00 2012 Clamp test delay set for: 1 minutes Cycle interval set for: 60 minutes Ascending timeout set for: 800 seconds Ascending trigger depth set for: 8.0 meters Descending timeout set for: 600 seconds Descending trigger depth set for: 50.0 meters Time to wait at surface set for: 0 seconds OpFile written successfully Waiting for the clamp test Present time........... Sun Jan 15 08:14:08 2012 Clamp test at.......... Sun Jan 15 08:15:08 2012 First profile at....... Sun Jan 15 10:00:00 2012 ----------------------- Sleeping till.......... Sun Jan 15 08:15:08 2012 ----------------------- Present time........... Sun Jan 15 08:15:09 2012 Starting clamp test CLIMB MODE Cam_sw: 1 Current: 0.349 Apk FREE MODE Cam_sw: 0 Current: 0.344 Apk Clamp test complete Present time........... Sun Jan 15 08:15:25 2012 Next profile at........ Sun Jan 15 10:00:00 2012 ----------------------- Sleeping till.......... Sun Jan 15 09:59:00 2012 -----------------------