Instrument Make: RMR - Remote Measurements & Research Company Model: RAD - Radiometer Analog to Digital Interface with Eppley PSP (Precision Spectral Pyra- nometer) and PIR (Precision Infrared Radiometer) S/N: RAD_222 Calibration Date: 2018-02-03 Installation: Installed on the top of the MET mast 08 March 2018 RAW datafile: MET 2016/03/14 22:22:50.683 RAD $WIR22,16/03/14,22:22:50, 175, -227.7, 323.05, 16.21, 15.06, 322.53, 20.2, 10.6 dsLog time stamp: MET 2016/03/14 22:22:50.683 RAD MET Meteorological Sensor 2016/03/14 date in gmt 22:22:50.683 time in gmt RAD data collected from the radiometers data $WIR22,16/03/14,22:22:50, 175, -227.7, 323.05, 16.21, 15.06, 322.53, 20.2, 10.6 Example Value Heading Description Unit $WIR22 ID NMEA-style tag. - 16/03/14 DATE yy/MM/dd GMT 22:22:50 TIME hh:mm:ss GMT 175 # the number of samples that went into the averages. - -227.7 PIR the average voltage from the PIR thermopile. millivolts 323.05 LW the computed longwave downwelling irradiance W m-2. 16.21 TCASE the PIR case temperature °C. 15.06 TDOME the PIR dome temperature °C. 322.53 SW the computed shortwave downwelling irradiance. W m-2. 20.2 T-AVR the temperature on the circuit board. °C. 10.6 BATT the battery voltage after the input diode drop volts ## NOTES WIR22 BOARD (REV B) VERSION: 1.17c, VERSION DATE: 2009,03,24 Digital Interface Board - Rev C. Feb 2009 Current datetime: 180321,122658 -----USER ENTER INFORMATION----------------------------- 'k' -->Set PSP coefficient (7.98E-6 v/(W/m^2)) 'K' -->Set PIR coefficient (2.64E-6 v/(W/m^2)) 'A' -->Change Identifier String. (22) -----RAD CALIBRATION DATA--------------------------------- 'g' -->Set PSP amplifier gain value. (118.8) 'o' -->Set PSP amplifier offset, mv. (0.1 mv) 'G' -->Set PIR amplifier gain value. (825.2) 'O' -->Set PIR amplifier offset, mv. (1.7 mv) 'C' -->Set Case 33274.0 ohms, -6.622e-5, 9.528e-2, -3.398e1 'D' -->Set Dome 33122.0 ohms, -4.220e-5, 7.334e-2, -2.929e1 'V' -->Set Thermistor Reference & ADC Reference Voltage (4.1 mV). Cmax = 2048 (fixed) ---------DATE & TIME SETTING------------------------------ 'T' -->Set the date/time. -----TIMING SETTING--------------------------------------- 'L' -->Set averaging time in seconds. (10) -----OTHER------------------------------------------------ 'S' -->Sample 12 bit A to D. 'r' --> toggle test mode. 'X' -->Exit this menu, return to operation. ========================================================= Command?>